Home  Products Search  Properties Search  中文版
Home > Dictionary > Information
sethoxydim
Molecular formula :
CAS :

nature : liquid boiling point of 90 ° C (44mPa). Solubility in water for 24.5mg/kg (25 ° C), general-soluble organic solvent, acute oral LD50> 2670mg/kg, acute percutaneous LD50 k> 5000mg/kg. Right skin irritation. Herbicide. To butene-2-aldehyde, Ethanethiol,, Acetoacetate sodium phenol, methyl malonic acid, the small chloride, ethoxy amine catalysts for the ingredients, Addition, cyclization, hydrolysis, decarboxylation, acylation, such as divorced obtained. In cotton, canola, soybean, beet crop control broadleaf annual and perennial weeds, dosage 0.2 ~ 0.5kg/ha.


Notice:Each item can have many explanations from different angels. If you want grasp the item comprehensively,please see below "more details data".
Structure:
Please see below "More Detailed Data"
More Detailed Data:
1) Sethoxydim;2-[1-(Ethoxyimino)butyl]-5-[2-(ethylthio)propyl]-3-hydroxy-2-cyclohexen-1-one;Poast
2) sethoxydim
3) 2-[1-(Ethoximino)butyl]-5-[2-(ethylthio)-propyl]-3-hydroxy-2-cyclohexen-1-one;2-[1-(Ethoxyimino)butyl]-5-[2-(ethylthio)propyl]-3-hydroxy-2-cyclohexen-1-one;Sethoxydim
4) Dilute Wo determined
5) 2-(1-(ethoxyimino)butyl)-5-(2-(ethylthio)propyl)-3-hydroxy-2-Cyclohexen-1-one;2-(1-(ethoxyimino)butyl)-5-(2-(ethylthio)propyl)-3-hydroxy-2-cyclohexen-1-one
6) 4,4'-diethoxythio-carbanilid;4,4'-diethoxythiocarbanilide;aethoksid;ethoxide (pharmaceutical);ethoxyd;etocarlide;etoksid;n,n'-bis(4-ethoxyphenyl)thiourea
Notice Some description was translated by software and the data is only as a reference.
Patent:
1) Hydrodynamic torque-converter internal play detection method
2) Form measuring device, form measuring method, form analysis device, form analysis program, and recording medium storing the program
3) Portable track geometrical status detection dolly
4) Method for sticking strain foils in polythene composite geomembrane deformation direct measuring and testing technique
5) Process for detecting moving object
6) Method for determining relative position of optical detection assembly and scanning platform
7) Method and apparatus for measuring coaxial relation between two mechanical parts
8) Urban underground miniature pipe depth measuring transducer based on CCD photosensitive elements
9) Compatible and accurate calibration method for double eye line structure photo-sensor and implementing apparatus
10) Non-contact fluid thickness detection system and method thereof